Fire Risk Assessments in HMOs: What's Actually Required Beyond the Fire Doors
Fire Risk Assessments in HMOs: What's Actually Required Beyond the Fire Doors
Most HMO landlords know fire doors matter. Far fewer can tell you who is actually required to carry out a fire risk assessment, how often it needs reviewing, or what a council fire officer expects to see in it when they turn up. Fire doors are one line item in that assessment, not the whole thing — and treating them as a substitute for the real document is one of the most common gaps CertMinder UK sees in HMO compliance.
The legal duty, and who it falls on
Under the Regulatory Reform (Fire Safety) Order 2005, anyone with control over a property used as an HMO — the landlord, or the managing agent where that responsibility has genuinely been delegated — is the "responsible person" for fire safety in the common parts. That duty is to carry out, and keep under review, a suitable and sufficient fire risk assessment covering the whole building: common escape routes, fire doors and their closers, fire detection and alarm coverage, emergency lighting where needed, and any specific hazards created by how the building is used.
This sits alongside, not instead of, the Housing Act 2004 licensing conditions that come with mandatory or additional HMO licensing. A council can and does ask to see the fire risk assessment as part of a licence application or renewal, and a missing or clearly inadequate one is a common reason for a licence to be refused or for improvement notices to follow.
What a proper fire risk assessment actually covers
A fire risk assessment is a structured document, not a mental checklist. For an HMO it should identify the fire hazards present, who is at risk (tenants, visitors, anyone with mobility or sensory impairments who might need extra provision), and then set out the control measures in place against each hazard. In practice, for a typical shared house or converted HMO, that means working through:
- Escape routes. Are they clear, unobstructed, and do they lead directly to a place of safety? Storage in hallways or under stairs is one of the most common findings against landlords.
- Fire doors and self-closers. Correctly fitted, undamaged, and actually self-closing — not propped open, which is the single most frequent failure found on inspection.
- Detection and alarm systems. The right grade of system for the size and layout of the HMO, maintained and tested, with records kept.
- Emergency lighting, where escape routes aren't adequately lit by natural or normal lighting.
- Management arrangements. Who checks the alarm weekly, who the tenants contact if something's wrong, and how that's actually recorded.
For most small HMOs this can be done competently by the landlord or agent using a recognised methodology (LACORS or the current national guidance most councils point to), provided it's genuinely thorough and documented. Larger or more complex HMOs — multiple storeys, converted buildings with unusual layouts, or anything the landlord isn't confident assessing properly — are exactly where a qualified fire risk assessor is worth paying for rather than guessing.
How often it needs reviewing
There's no fixed statutory interval, which is precisely why it gets neglected. The requirement is to review it when circumstances suggest it's no longer valid: a change of tenant mix, building work, a new fire door fitted, an incident or near-miss, or simply the passage of time making it worth a fresh look. Most councils expect to see evidence of review at least annually for licensed HMOs, and a document that's three or four years old with no sign anyone has looked at it again is treated the same as having no assessment at all.
Where this catches landlords out
It's rarely the assessment itself that's missing entirely — it's that it was done once, at the start of the tenancy or the licence application, and then never looked at again. A tenant changes a lock, blocks a corridor with belongings, or props a fire door open with a wedge for ventilation, and none of it gets picked up because nobody's checking against the document. The fire risk assessment is only useful if it's a living record tied to actual management of the building, not a certificate filed away and forgotten.
Where CertMinder UK fits, and where it doesn't
We don't carry out fire risk assessments, and we're not going to pretend a generic checklist in an app replaces a properly reasoned document for a building we've never seen. What CertMinder UK does is make sure the assessment you already have doesn't quietly go stale: logging when it was done, setting a review reminder, and keeping it alongside your HMO licence, EICR and Gas Safety records so a council officer — or you, at 11pm the night before an inspection — can find everything in one place rather than across three email accounts and a filing cabinet.
The bottom line
A fire risk assessment is the actual legal requirement; fire doors are one control measure within it. If you manage an HMO and your fire safety compliance consists of "the doors are fine," it's worth checking whether a genuine, dated, reviewed fire risk assessment exists for the building — and if it does, whether anyone has looked at it since it was written.
This article is informational and does not constitute legal advice. Fire safety requirements can vary by building type, number of occupants, and local authority licensing conditions. Check current government guidance or seek a professional fire risk assessment for your specific property.